two runs of the gaze calibration died in a row and both times it looked like user error, meaning me, which was the wrong diagnosis twice. the bugs were in my own calibrator. the first one was nasty: a single bad anchor, a ring i missed or a look that wandered during its second, bent the entire gaze map to accommodate it. the fit still passed, and the verify step caught the wreckage, but the fix had to be structural.
the calibrator now detects the polluted anchor, drops it, refits on the remaining eight anchors, and verifies the result again, so one bad look can no longer kill a run. the second bug was pace. the verify rings gave about a second per ring, and landing late or reading the pill at the bottom of the screen mixed junk into the readings. the rings now travel slower and the first two tenths of a second of every reading is thrown away so arrival lag does not count.
also added two voice commands that should have existed ages ago, calibrate point and a bare where, instead of both falling into the draft buffer. the whole suite is green at seventy three tests, and the last two real failures were my code, not the person using it, which is the best outcome a debugging session can have.